Aircommand IBIS ROOFTOP CARAVAN Instruções de Operação

Consulte online ou descarregue Instruções de Operação para Aparelhos de ar condicionado "split system" Aircommand IBIS ROOFTOP CARAVAN. Aircommand IBIS ROOFTOP CARAVAN Operating instructions Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 13
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
1
\
INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS
ROOFTOP AIRCONDITIONER
Suitability:
The IBIS caravan rooftop aircondioner is suitable for installation on caravans
and motorhomes provided the roof structure is suitable and the installed position
allows for reasonable air circulation within the van.
A central installed position is recommended to allow for even air distribution
throughout the van. In difficult positions the airdistribution plenum may be set at right
angles to the fore/aft direction of the van
Fig 1
The installed weight of a unit is 46 KG and the roof structure must be strong enough
to carry this load. If in doubt always use an H” frame to spread the load out to the
walls. See Figs. 1 & 2 for details.
Vista de página 0
1 2 3 4 5 6 ... 12 13

Resumo do Conteúdo

Página 1

1\ INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER Suitability: The IBIS caravan rooftop aircondioner is suitable for installati

Página 2

10 Fig 16 Commissioning of the unit: (see also instructions to operate controls) Turn on the circuit breaker to energise unit. The unit may b

Página 3

11Set temperature a few degrees below room temperature. Note: The digital readout = actual room temp. Press down or up arrow the readout will blink

Página 4

12After the delay, the compressor will start. Usually the fan will stop and will not re energize until the heat exchanger has warmed and then the fa

Página 5

13 OPERATION USING THE REMOTE HANDPIECE: Be sure to point the signal transmitter at the main control on the plenum. All functions are available as p

Página 6

2 Fig 2 The unit must not be installed more than 5 degrees out of level fore / aft. The 240 V 50Hz power supply must be protected with a 15 Amp

Página 7

3 Before installing the unit over the square hole, clean the roof around the hole to remove any grease etc. See Fig 4.

Página 9

5 Fig 7 Connection of power supply: See Fig. 8 The power cable can now be connected via the terminal block located on the underside

Página 10

6Measure the distance from the fan discharge tube, after the unit is clamped down to the ceiling. This is dimension “A” Add 15mm which is the

Página 11

7 Now the duct can be engaged with the extension duct and pushed up firmly against the ceiling. NB the extension duct should fit snuggly into the fo

Página 12

8 Fig 12 Fig 13

Página 13

9 Fig 14 Now fit facia to duct and screw the 4 securing screws up into the duct. Figs 12 , 13 & 14. Remove the return airfilters and

Comentários a estes Manuais

Sem comentários